Type of construction

  • RCC foundation - complying with seismic code requirements.
  • RCC frame structure with block work. The height of each floor shall be 9’6”.

Flooring & wall finishing

  • Lift Lobby: Wall and floor Colored granite as per Architect design.
  • Staircases: Granite flooring with SS hand Railing as per Architect design.
  • Car park Area: Grano flooring with grooves.
  • Foyer, living/dining, kitchen: Premium 4’x 6’ and all bedrooms: Premium 2’ x 4‘ vitrified tile flooring with 4” Skirting.
  • Toilets: Design tile concepts up to roof.
  • Balconies: Antiskid tiles with MS railings.
  • Service Area: 3‘0” ht dado tiles all 3 sides.
  • Kitchen counter: Galaxy B1aclk granite counter of 18mm thickness with dado tiles above counter up to 2’0" ht.

Wall, Ceiling & Joinery Treatment

  • Internal walls and ceilings - 2 coats putty,1 coat primer and 2 coats emulsion roller finish.
  • External walls and stilt floor columns and walls - 1 coat primer and 2 coats exterior emulsion.
  • Joinery - All Internal doors enamel paint over primer/laminated Main door - Varnish finish on both sides.

Plumbing & sanitary fittings

  • Sanitary fittings: EWC wall-hung of Hindware/Jaquar or equivalent with concealed cistern.
  • Faucets: All Faucets shall be single lever Hindware/Jaguar or equivalent make.
  • Plumbing: All water supply lines shall be CPVC pipes. Drainage lines and storm water drain pipes shall be in PVC.
  • Kitchen & Service Area: Wall-mounted faucet would be provided and one SS sink with drain board.
  • Bore well with required depth equipped with motor.
  • Adequate underground sump of 12000 litres and over head tank of 6000 litres with automatic water level controller as per MEP design.
  • Pressure pump will be provided with adequate pipeline capacity to take the load. Rainwater harvesting will be done.

Elevator

  • Elevators: 8-passenger capacity 1 no. lift with automatic doors and spray paint finish to match building Scheme. (Lift access will be provided up to terrace floor)

Doors & Windows

  • Window Shutters: UPVC sliding windows with plain glass and mosquito net.
  • Main door - Frame and shutters of solid Teakwood. Handles, Tri-bolt lock of Europa/Yale/Godrej equivalent make with antique hardware.
  • Main door - Frame and shutters of solid Teakwood. Handles, Tri-bolt lock of Europa/Yale/Godrej equivalent make with antique hardware.

Windows & Ventilators

  • Windows and Ventilators shall be made of UPVC with reputed brands.
  • Hardware: All hardware shall be CP Brass, tower bolts, doors stoppers, ball bearing hinges. Locks shall be mortise of Dorset or equivalent make.

Electrical

  • Concealed copper wiring of Anchor or equivalent make.
  • Electrical Modular switches of Anchor / Legrand or equivalent.Concealed copper wiring of Anchor or equivalent make.
  • Switches: All switches shall be Anchor by Panasonic - Roma or equivalent make.
  • 35 KVA Generator: Power backup will be provided for all common services including Lift, Power backup for flats - s lights, 5 fans, 1 fridge, living room TV, 1 l0amps. socket in living room, kitchen and master bedroom.
  • Common area and external Light fittings would be provided. Solar panels would be provided as per the CMDA by-laws. The power generated would be connected to the common power grid.
  • Automatic EB-DG phase changer will be provided.
  • All main switchboards in each bedroom, living room and dining room additional 5A socket will be provided.

Car Parking

  • 1 no. covered car parking would be provided to every apartment.
  • One l5amp. plug point socket will be provided for each car park for EV charging.

Terrace

  • Landscaped area and gathering space will be provided on the terrace as per feasibility and architect’s design.
  • Open landscape area with seating and planter box will be provided with necessary features such as statue and lighting.

External Area Finish

  • Interlock pavers/parking tiles to be laid in driveways.
  • Landscape - As per site feasibility and architect’s design.

External Area Finish

  • Front Facade would be executed as per Architect’s Facade Design. Compound Wall - Front compound wall would be executed as per Architect's design of 6 feet height.
  • Front facade and front compound wall as per the Architect Design.